首页> 外文会议>Biotech, biomaterials and biomedical >Nanobiomimetic Memristor/Memcapacitor Devices Used for Direct and Reagent-less Detection of Sub pM Acetyl Coenzyme A in Milks
【24h】

Nanobiomimetic Memristor/Memcapacitor Devices Used for Direct and Reagent-less Detection of Sub pM Acetyl Coenzyme A in Milks

机译:纳米仿生忆阻器/电容器电容器器件,用于直接和无试剂检测牛奶中的亚pM乙酰辅酶A

获取原文
获取原文并翻译 | 示例

摘要

Milk quality is key to the wellness of human babies, and detecting essential benefits and critical deficiencies in different types of milk is a crucial element to assuring good brain development. Acetyl co-enzyme A (AcCoA) is a leading substrate in a large variety of enzyme-catalyzed reactions. Unbalanced regulation of AcCoA leads to many diseases, such as diabetes, cancer, coronary disease, schizophrenia, sudden infant death syndrome and Alzheimer's. We developed a biomimetic memristor/memcapacitor sensor for direct measure sub pM concentrations of AcCoA under the conditions of free from antibody and labeling tracers, and is reagent-less. The signal changes of AcCoA over a wide concentrations range between 2 pM to 0.3μM were measured by the chronoamperometry (CA) method; it has a linear range from 2 pM to 0.4 nM. The value of Detection of Limits (DOL) is 1.2×10~(-12)M/cm~2. AcCoA spiked milk specimens were measured with a recovery value of 103%, and the method produced an error of less than 2% (n=12) by using milk samples. We studied the energy impact of human milk and USDA certified organic milk for infants upon the neuronal synapse action / resting potential pulses with and without AcCoA at slow-wave-sleeping (SWS) and 250 Hz, respectively. The results indicate that human milk has a 5-fold higher energy outcome for infants than organic milk at SWS for benefiting brain development, and human milk is orders of magnitudes sensitive for communicating with the sensor when AcCoA occurred than in organic milk when a double step chronopotentiometry (DSCPO) method was used.
机译:牛奶的质量是婴儿健康的关键,而检测不同类型的牛奶的基本益处和严重缺陷对确保大脑良好发育至关重要。乙酰辅酶A(AcCoA)是多种酶催化反应中的主要底物。 AcCoA调节不平衡会导致许多疾病,例如糖尿病,癌症,冠心病,精神分裂症,婴儿猝死综合症和阿尔茨海默氏病。我们开发了一种仿生忆阻器/电容器传感器,可在无抗体和标记示踪剂的条件下直接测量AcCoA的亚pM浓度,而且无试剂。通过计时电流法(CA)测量了AcCoA在2 pM至0.3μM的宽浓度范围内的信号变化;它的线性范围为2 pM至0.4 nM。极限检测(DOL)的值为1.2×10〜(-12)M / cm〜2。测量的AcCoA加标牛奶样品的回收值为103%,该方法使用牛奶样品产生的误差小于2%(n = 12)。我们研究了在慢波睡眠(SWS)和250 Hz下,有或没有AcCoA的人乳和USDA认证有机乳对婴儿的神经元突触动作/静息电位脉冲的能量影响。结果表明,人类乳汁有益于大脑发育,在SWS时婴儿的能量结果比有机乳汁高5倍,并且当发生AcCoA时,人类乳汁对传感器与传感器的通讯要比通过双步进行时有机乳汁高出几个数量级。计时电位法(DSCPO)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号