首页> 外文会议>ASNT fall conference quality testing show >Probability of Detection (POD) Analysis for Magnetostrictive Sensor (MsS) Guided Wave System on 4-inch Diameter Pipe
【24h】

Probability of Detection (POD) Analysis for Magnetostrictive Sensor (MsS) Guided Wave System on 4-inch Diameter Pipe

机译:4英寸直径管道上的磁致伸缩传感器(MsS)导波系统的检测概率(POD)分析

获取原文

摘要

Guided waves have been used for many years to survey pipes over a long distance for a single probe location. The standard convention is that most guided wave systems can detect defects on the order of 5% of the total pipe wall cross section with the understanding that pipe coatings, whether the pipe is buried or not, and general condition of the pipe can ultimately affect this detection sensitivity. The industry is now trying to get a better understanding of the probability of detection (POD) of the guided wave method. POD determination is conditional upon pipe geometry, type of anomaly, and factors determined by the design of each particular guided wave testing (GWT) system. In this paper, a preliminary investigation of the POD for magnetostrictively generated guided waves is described for 4-inch diameter pipe. The POD results are provided along with the parameters that affected the POD results.
机译:多年来,一直使用导波在单个探头位置测量长距离管道。标准惯例是,大多数导波系统可以检测到总管壁横截面的5%左右的缺陷,但要了解管道涂层,管道是否被埋入以及管道的总体状况最终会影响这一点。检测灵敏度。业界现在正试图更好地理解导波方法的检测概率(POD)。 POD的确定取决于管道的几何形状,异常类型以及由每个特定的导波测试(GWT)系统的设计确定的因素。在本文中,描述了对直径为4英寸的管道的磁致伸缩产生的导波的POD的初步研究。提供POD结果以及影响POD结果的参数。