首页> 外文会议>Advanced sensor systems and applications VII >Multimode interference structures as sensing elements integrated into Mach-Zehnder interferometers in polymer foils
【24h】

Multimode interference structures as sensing elements integrated into Mach-Zehnder interferometers in polymer foils

机译:多模干涉结构作为传感元件集成到聚合物箔片的Mach-Zehnder干涉仪中

获取原文
获取原文并翻译 | 示例

摘要

Integrated Mach-Zehnder interferometers (MZIs) based on flexible polymer materials have been demonstrated as evanescent field sensors for the detection of refractive indices and molecule concentrations. The used application of a measurement window in classical MZIs is difficult in a roll-to-roll fabrication process. We have previously demonstrated foil-based asymmetric MZIs with different widths in sensing and reference arm which do not need a measurement window. Here we present the use of a multimode interference structure (MMI) inserted into the sensing arm of the interferometer to increase the sensitivity. We consider the expected interference signal from numerical simulations and optimize the system in terms of sensitivity, dimensions and absorption losses. The fabricated MMI-MZI foils are tested experimentally to demonstrate the function of the MMI-MZI system by applying water/glucose solutions with different refractive indices.
机译:基于挠性聚合物材料的集成马赫曾德尔干涉仪(MZI)已被证明是用于检测折射率和分子浓度的瞬逝场传感器。在卷对卷制造过程中,很难在经典MZI中使用测量窗口。先前我们已经展示了基于箔的非对称MZI,其感应臂和参考臂具有不同的宽度,不需要测量窗口。在这里,我们介绍了使用多模干涉结构(MMI)插入干涉仪的传感臂中以提高灵敏度的方法。我们考虑了来自数值模拟的预期干扰信号,并在灵敏度,尺寸和吸收损耗方面优化了系统。对制成的MMI-MZI箔进行了实验测试,通过施加具有不同折射率的水/葡萄糖溶液来证明MMI-MZI系统的功能。

著录项

  • 来源
    《Advanced sensor systems and applications VII》|2016年|100250v.1-100250v.10|共10页
  • 会议地点 Beijing(CN)
  • 作者单位

    Gisela and Erwin Sick Chair of Micro-optics, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Gisela and Erwin Sick Chair of Micro-optics, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Gisela and Erwin Sick Chair of Micro-optics, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Gisela and Erwin Sick Chair of Micro-optics, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Laboratory for Materials Processing, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Laboratory for Process Technology, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

    Gisela and Erwin Sick Chair of Micro-optics, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Mach-Zehnder interferometers; multimode interference structure; refractive index sensors; evanescent field sensor;

    机译:马赫曾德尔干涉仪;多模干扰结构;折射率传感器;消逝场传感器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号