首页> 外文会议>26th International Symposium for Testing and Failure Analysis, Nov 12-16, 2000, Bellevue, Washington >Humidity-Bias Driven Shorts in Multilayer Circuits: A Case Study in Failure Analysis
【24h】

Humidity-Bias Driven Shorts in Multilayer Circuits: A Case Study in Failure Analysis

机译:多层电路中由湿气引起的短路:故障分析中的案例研究

获取原文
获取原文并翻译 | 示例

摘要

When a failure analysis (FA) involves a multiple layer structure separated by a polymeric material such as Benzocyclobutene (BCB), in a plastic package, it becomes a very challenging task to find out where the failure site is and how it failed. This is due to the fact that the chemical de-processing procedure removes BCB as well as the plastic molding compound. This paper outlines the studies earried out to determine the failure site and the root cause of the failure mechanism in a multilayer circuit and the steps taken to fix the problems. The methodology and results of this study are applicable to many other types of circuits.
机译:当故障分析(FA)涉及在塑料包装中由诸如苯并环丁烯(BCB)之类的聚合材料隔开的多层结构时,找出故障部位和故障方式变得非常艰巨。这是由于以下事实:化学脱模过程会去除BCB以及塑料模塑料。本文概述了为确定多层电路中的故障部位和故障机理的根本原因而进行的研究,以及为解决这些问题而采取的步骤。这项研究的方法和结果适用于许多其他类型的电路。