This paper presents a study of metasurface integrated uncooled infrared (IR) silicon germanium oxide (Si-Ge-O) microbolometers for Long Wavelength Infrared (LWIR) detection. The inclusion of the metasurface permits engineering the IR absorptance with respect to wavelength. Absorption by the metasurface eliminates the need for a ¼-wave resonant cavity under the microbolometer. In addition, the metasurface can significantly improve the electrical performance of the temperature-sensing layer. Experimental results show an increase in the Temperature Coefficient of Resistance (TCR) and a decrease in the resistivity of the amorphous Si-Ge-O films. These parameters scale with the periodicity and area fraction of the metasurface. The voltage noise power spectral density was reduced by annealing the devices in vacuum. The measured responsivity and detectivity approached 104 V/W and 109 cm Hz1/2/W to filtered blackbody infrared radiation.
机译:本文介绍了一种用于超长波长红外(LWIR)检测的超表面集成非冷却红外(IR)硅锗氧化物(Si-Ge-O)微辐射热计。包含超颖表面允许设计关于波长的IR吸收率。超表面的吸收消除了在微辐射热计下的1/4波谐振腔的需要。另外,超颖表面可以显着改善温度感测层的电性能。实验结果表明,非晶硅-锗-氧薄膜的电阻温度系数(TCR)增大,电阻率减小。这些参数与超表面的周期性和面积分数成比例。通过在真空中对器件进行退火,可以降低电压噪声功率谱密度。测得的响应度和检测率接近10 \ n 4 \ n V / W和10 \ n 9\n cm Hz \ n 1/2 \ n / W过滤黑体红外辐射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号