首页> 外文会议>2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits >Case Study on Wire Bonding - Related Partial Discharge on High-Voltage Isolators
【24h】

Case Study on Wire Bonding - Related Partial Discharge on High-Voltage Isolators

机译:高压隔离器的引线键合相关局部放电的案例研究

获取原文
获取原文并翻译 | 示例

摘要

Most devices which failed during High Voltage Isolation Testing seen a lateral dielectric breakdown after decapsulation. Failure analysis results explained the irregularity in IC assembly process causing the partial discharge that leads to dielectric breakdown, called treeing. This explanation together with root cause verification and wire bond parameter simulation from assembly process pointed out that the improper parameter modification resulted to electrical treeing.
机译:多数在高压隔离测试中失败的设备在拆封后都会发生横向介电击穿。故障分析结果解释了IC组装过程中的不规则性,该不规则性导致了导致介电击穿的局部放电,称为树。该解释以及根本原因验证和装配过程中的引线键合参数仿真指出,不正确的参数修改会导致电气树。