The comparative study of four-phase switched reluctance motor turn-on angle based on Simulink

机译:基于Simulink的四相开关磁阻电动机接通角的比较研究

获取原文
获取原文并翻译 | 示例

摘要

Based on the analysis of structure principle and drive system of switched reluctance motor, switched reluctance motor model has been established by Simulink moduel. By changing the parameter of turn-on angle in the model, the corresponding phase current was collected for comparative analysis. It's concluded that the larger the turn-on angle, the smaller the amplitude of linear increase of the current, which has provided an effective reference for physical design of four-phase 8/6 pole switched reluctance motor.
机译:在分析开关磁阻电机的结构原理和驱动系统的基础上,利用Simulink moduel建立了开关磁阻电机模型。通过改变模型中的导通角参数,收集相应的相电流进行比较分析。结论是,导通角越大,电流线性增加的幅度越小,这为四相8/6极开关磁阻电机的物理设计提供了有效的参考。