An energy shortage arose in Lebanon during and after the civil war (1975-1990).62% of the national electricity generation is consumed by building stock, of which 70/0 is consunled in the conlnlercial sector. Given the acute shortages and increased consumnption, there is a need to rationalise the use of energy in the building sector. There is growing evidence that buildings which adopt passive design solutions, such as daylighting and natural ventilation, have good energy performance and show higher occupant satisfaction. Daylighting can be a good contributor to energy efficiency in the buildings of Beirut. where the climate is typically Mediterranean and daylight is available 12 hours per day on average. During the last century, the development of façade configurations and the widespread adoption of international design trends in Beirut, particularly in office buildings, changed the energy consumption pattern. The lack of any building regulations that considered the potential of daylighting led to an underestimation of the impact of façade design on the internal environment and building energy behaviour. The aim of this study is to develop design guidelines for office building façade configuration and plan morphology that will contribute to the best use of daylighting, with associated potential energy savings, in Beirut. To achieve this, the study has three main parts. Firstly, the literature relating to daylighting design principles, glazing façades and human comfort in workspaces is reviewed in order to identify design parameters and variables that are significant for daylighting performance in office buildings. Thereafter, the seven historical phases of architectural development in Beirut are identified. Examples of office buildings from each phase are evaluated for their daylighting efficiency, in accordance to four parametric levels describing the 'Building Shape, 'Window/Façade' and Window/Office' relationships, and the 'Shading Devices' used. Finally, the lighting behaviour of 14 selected case studies is simulated using ADELINE. Electrical lighting consumption and the possible savings due to the implementation of different lighting control strategies are calculated. The simulation outputs are validated by empirical energy data. Finally design guidelines for the best practice in the office buildings of Beirut are produced, by coupling the evaluation of daylighting design variables and energy savings measures.
机译:内战期间和之后(1975-1990年),黎巴嫩出现了能源短缺。建筑用电量消耗了全国发电量的62%,其中70/0的电量消耗在了娱乐业。考虑到严重的短缺和消耗增加,有必要对建筑部门的能源使用进行合理化。越来越多的证据表明采用被动设计解决方案(例如采光和自然通风)的建筑物具有良好的能源性能,并显示出较高的居住者满意度。采光可以成为贝鲁特建筑节能的重要因素。那里通常是地中海气候,平均每天有12个小时的白天可用。在上个世纪中,立面配置的发展以及贝鲁特(尤其是办公楼)国际设计趋势的广泛采用改变了能耗模式。缺乏考虑日光照明潜力的建筑法规,导致人们低估了立面设计对内部环境和建筑能耗的影响。这项研究的目的是针对贝鲁特的办公建筑立面配置和规划形态制定设计指南,这将有助于最佳利用采光,并带来潜在的节能效果。为了实现这一目标,研究包括三个主要部分。首先,回顾了有关采光设计原理,玻璃幕墙和工作空间中人类舒适度的文献,以确定对办公大楼采光性能重要的设计参数和变量。此后,确定了贝鲁特建筑发展的七个历史阶段。根据描述“建筑物形状”,“窗户/立面”和“窗户/办公室”之间的关系以及所使用的“遮光设备”的四个参数级别,评估了每个阶段的办公楼实例的采光效率。最后,使用ADELINE模拟了14个选定案例研究的照明行为。计算了电气照明消耗以及由于实施不同的照明控制策略而可能节省的费用。仿真输出通过经验能量数据进行验证。通过结合对采光设计变量的评估和节能措施,最终得出了贝鲁特办公楼最佳实践的设计指南。

著录项

  • 作者

    Saridar Sawsan Mohamad;

  • 作者单位
  • 年度 2004
  • 总页数
  • 原文格式 PDF
  • 正文语种 English
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号