首页> 外文OA文献 >Effect of denture cleansers on metal ion release and surface roughness of denture base materials
【2h】

Effect of denture cleansers on metal ion release and surface roughness of denture base materials

机译:义齿清洁剂对义齿基托金属离子释放及表面粗糙度的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.
机译:化学消毒剂通常与去除污渍和减少生物膜形成的机械方法相关。这项研究模拟了180次浸泡试验,评估了消毒剂对市售纯钛,金属合金和热聚合丙烯酸树脂释放金属离子和表面粗糙度的影响。圆盘状样品由商业纯钛(Tritan),镍铬钼钛(Vi-Star),镍铬(Fit Cast-SB Plus)和镍铬铍(Fit Cast-V)制成合金。将每个铸造盘投入烧瓶中,将金属盘结合到热聚合的丙烯酸树脂中。将样品(n = 5)浸入以下溶液中:0.05%的次氯酸钠,Periogard,Cepacol,Corega Tabs,Medical Interporous和Polident。用去离子水作为对照。使用电感耦合等离子体质谱法(ELAN DRC II)对金属离子释放进行定量分析。使用表面分析仪(Surftest SJ-201P)测量表面粗糙度(μm)。在浸泡之前和之后记录数据,并通过双向方差分析和Tukey检验(α= 0.05)进行评估。浸入医用多孔材料后,Vi-Star和Fit Cast-V合金的镍释放量被证明是最重要的。浸渍后,树脂的表面粗糙度存在显着差异(p = 0.011)。 cepacol导致明显更高的树脂粗糙度。浸没产物对金属粗糙度没有影响(p = 0.388)。可以得出结论,被测试的合金可以被认为可安全地用于可移动义齿的制造,但是应谨慎使用用于每日义齿浸泡的消毒液,例如Cepacol和Medical Interporous片剂,因为它们分别导致更大的树脂表面粗糙度和更大的离子释放。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号