Many of the clean agents currently used in total flooding fire suppression applications have vapor densities greater than ambient air. The denser agent-air mixture creates hydrostatic pressure differences causing flow of the mixture out of the enclosure as well as flow of ambient air in through leakage paths inherent in building construction. Hold time refers to the amount of time it takes for the concentration of the agent-air mixture to drop below a specified concentration at a designated height within the protected enclosure. In this study an experimental test enclosure was used to evaluate an analytical model of agent-air mixture leakage and to investigate the effects of different leakage areas on agent hold times. The analytical model, known as the descending interface model, demonstrated favorable agreement with experimental measurements for heights greater than one-half the height of the enclosure for the agent used in this investigation.
机译:当前用于全水淹灭火应用中的许多清洁剂的蒸气密度大于环境空气。致密的空气介质混合物产生静水压力差,导致混合物流出外壳,以及周围空气通过建筑物固有的泄漏路径流入。保持时间是指在受保护的密闭空间内,代理空气混合物的浓度在指定高度下降到指定浓度以下所需的时间。在这项研究中,使用了一个实验测试箱来评估药剂-空气混合物泄漏的分析模型,并研究不同泄漏面积对药剂保持时间的影响。该分析模型称为降序界面模型,该模型与实验测量结果吻合良好,该高度大于用于此研究的试剂的外壳高度的一半。

著录项

  • 作者

    ORourke Sean Thomas;

  • 作者单位
  • 年度 2005
  • 总页数
  • 原文格式 PDF
  • 正文语种 en_US
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号