Changes in the visualization of non-ionic contrast medium (Omnipaque 300) in the urography by DIP were monitored for the normal sided urinary tract in patients with urolithiasis using a densitometer. In addition, changes of the visualization in relation to the dose of contrast medium used was examined and compared with that of ionic contrast medium (60% Urografin). The optimum photographing time was 15 minutes in the upper urinary tract (nephrogram, calyx, pelvis, upper ureter) and 20 minutes in the lower urinary tract (lower ureter, urinary bladder). Visualization of high usefulness appeared to be obtainable for the imaging diagnosis by DIP in subjects with normal renal function even when the photographing was completed 20 minutes after infusion of contrast medium. In relation to the doses of contrast medium used, no difference was observed in the variation pattern but a better imaging was obtained in the 100 ml group than 50 ml group with a significant difference (P less than 0.01) in the 15-20 minute images of the calyx and pelvis of the kidney and urinary bladder in particular, this suggested the high usefulness of 100 ml dosing for the imaging diagnosis. In the visualization of ionic contrast medium, some difference was observed in the variation pattern and the visualization was better in Ominpaque 300 groups than in 60% Urografin group with a significant difference (P less than 0.01) in the 15-20 minute images of the calyx and pelvis of the kidney and urinary bladder. This suggested the high usefulness of non-ionic contrast medium.
机译:使用光密度计监测尿路结石患者正常侧尿路,通过DIP监测尿路造影中非离子造影剂(Omnipaque 300)的可视化变化。此外,检查了与所使用的造影剂剂量有关的可视化变化,并将其与离子型造影剂(60%尿移植素)进行了比较。最佳拍摄时间在上尿路(肾盂造影,肾盂,骨盆,上输尿管)为15分钟,在下尿路(下输尿管,膀胱)为20分钟。即使在输注造影剂后20分钟完成照相,对于肾功能正常的受试者,通过DIP进行影像学诊断似乎也可以获得很高的实用性。关于使用的造影剂剂量,变化模式没有观察到差异,但是100 ml组比50 ml组获得了更好的成像,在15-20分钟的图像中有显着差异(P小于0.01)。特别是对于肾和膀胱的花萼和骨盆,这表明100 ml剂量对影像学诊断非常有用。在离子造影剂的可视化中,观察到变化模式有一些差异,Ominpaque 300组的可视化效果好于60%尿移植素组,在15-20分钟的图像中有显着性差异(P小于0.01)。肾和膀胱的花萼和骨盆。这表明非离子型造影剂的高度实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号