首页> 外文OA文献 >Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes
【2h】

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

机译:掌侧可变角锁定板的手术治疗不稳定的Dis骨远端骨折:临床和放射学结果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures.ududObjectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates.ududPatients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome.ududResults: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases.ududConclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
机译:背景:不稳定的远端radius骨骨折很难处理,因此已描述了各种治疗方式。 ud ud目的:本研究旨在评估使用可变角度锁定板治疗的不稳定远端radius骨骨折的功能和放射学结果。 ud ud方法:我们回顾了23处不稳定的远端radius骨骨折,这些骨折在我们机构中采用掌侧可变角度锁定板治疗。患者的平均年龄为32.82±11.81岁(范围19至62),平均随访时间为11.04±2.47个月(范围6至15)。所有患者均接受了可变角度锁定板的切开复位内固定术。放射学参数,例如radial骨倾斜度,长度,倾斜度和尺骨变化,在第6周和最后的随访时进行测量。通过测量腕关节的活动范围以及握力来进行功能评估。结果使用了Gartland和Werley的成绩评分系统来评估最终结果。 ud ud结果:有2例表面感染病例对口服抗生素有反应。一名患者出现了肥厚性瘢痕,而另一名患有腕管综合征,经保守处理。从六个星期到最后的随访,功能指标有了显着改善,同时保持了放射学参数。根据Gartland和Werley的研究,在65.2%的病例中报告了优异的结果,而在35%的病例中报告了良好的结果。 ud ud结论:使用可变角度的锁定板治疗不稳定的远端radius骨骨折与功能良好,并发症少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号