Evaluating the drinking waters microbial flora of reverse osmosis treatment systems in kashan city during summer and autumn (2015)

机译:评估夏季和秋季(2015年)喀山市反渗透处理系统饮用水中的微生物区系

摘要

According to the various difficulties of Distillation desalination system,currently the membrane technology such as Reverse Osmosis (RO) is more useful. High concentration of dissolve solids in supplying water resources in Kashan caused a bad taste and reduced the consumer’s desire for using such water,and often they used treated water in a way that at the conducting time of this study,20 centers treated the water by RO method in the city. Therefore,this study evaluated the microbial flora of produced drinking water of RO treatment system in Kashan city during summer and autumn 2015. In this study the census method have used and the sampling have done from all the RO water treatment centers of the city. Three input,output and after storage,samples have taken. The evaluation of the temperature,residual chlorine,TDS,the storage time,and RO membrane operation time in samples have done. The HPC test has done on the samples in the laboratory and the positive plates have identified in terms of bacterial spices. The tests have repeated in four months of the year from July to October. The results showed 95% residual chlorine in the input samples and the HPC test for these samples showed no contamination. The sample contamination after treatment and the tank were 8 and 15% respectively. In addition,the most contamination level have related to September,which the samples temperature in this month reach its highest level. The Pearson coefficient results showed that there was a significant relation between the Heterotroph colonies number and the residual chlorine and temperature parameters,which was consistent with Karami et al. in Kermanshah and Dobaradaran et al. in Esfahan studies. In addition,there was a significant relation between the Heterotroph colonies number and storage time and RO membrane operation time.
机译:鉴于蒸馏淡化系统的种种困难,目前反渗透(RO)等膜技术更为实用。喀山供水中溶解性固体的高浓度造成了不良味道,降低了消费者使用此类水的意愿,并且他们经常使用经过处理的水,使得在本研究进行时,有20个中心通过RO对水进行处理。在城市中的方法。因此,本研究评估了2015年夏季和秋季在喀山市RO处理系统产生的饮用水中的微生物区系。本研究使用普查方法,并从该市所有RO处理中心进行了采样。三个输入,输出以及存储后的样本。对样品中的温度,残留氯,TDS,储存时间和反渗透膜操作时间进行了评估。 HPC测试已在实验室中的样品上进行,阳性板已根据细菌香料鉴定。从7月到10月,测试在一年的四个月中重复进行。结果表明,输入样品中残留的氯含量为95%,而这些样品的HPC测试表明没有污染。处理后的样品污染和储罐的污染分别为8%和15%。另外,污染程度最高的年份与9月份有关,该月份的样品温度达到最高水平。皮尔森系数结果表明,异养菌菌落数与残留氯和温度参数之间存在显着关系,这与Karami等人的观点一致。在Kermanshah和Dobaradaran等人。在伊斯法罕研究中。另外,异养菌菌落数与保存时间和反渗透膜操作时间之间存在显着的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号