首页> 外文OA文献 >The Repeated sit-to-stand maneuver is a superior method for cardiac baroreflex assessment : a comparison with the modified Oxford method and Valsalva maneuver
【2h】

The Repeated sit-to-stand maneuver is a superior method for cardiac baroreflex assessment : a comparison with the modified Oxford method and Valsalva maneuver

机译:反复的从坐到站操作是评估心脏压力反射的一种更好的方法:与改良的Oxford方法和Valsalva操作的比较

摘要

Baroreflex assessment has diagnostic and prognostic utility in the clinical and research environments, and there is a need for a reliable, simple, noninvasive method of assessment. The repeated sit-to-stand method induces oscillatory changes in blood pressure (BP) at a desired frequency and is suitable for assessing dynamic baroreflex sensitivity (BRS). However, little is known about the reliability of this method and its ability to discern fundamental properties of the baroreflex. In this study we sought to: 1) evaluate the reliability of the sit-to-stand method for assessing BRS and compare its performance against two established methods (Oxford method and Valsalva maneuver), and 2) examine whether the frequency of the sit-to-stand method influences hysteresis. Sixteen healthy participants underwent three trials of each method. For the sit-to-stand method, which was performed at 0.1 and 0.05 Hz, BRS was quantified as an integrated response (BRSint) and in response to falling and rising BP (BRSdown and BRSup, respectively). Test retest reliability was assessed using the intraclass correlation coefficient (ICC). Irrespective of frequency, the ICC for BRSint during the sit-to-stand method was ≥0.88. The ICC for a rising BP evoked by phenylephrine (PEGain) in the Oxford method was 0.78 and 0.5 for the remaining measures. During the sit-to-stand method, hysteresis was apparent in all participants at 0.1 Hz but was absent at 0.05 Hz. These findings indicate the sit-to-stand method is a statistically reliable BRS assessment tool and suitable for the examination of baroreflex hysteresis. Using this approach we showed that baroreflex hysteresis is a frequency-dependent phenomenon.
机译:Baroreflex评估在临床和研究环境中具有诊断和预后功能,因此需要一种可靠,简单,无创的评估方法。重复的从坐到站方法会在所需频率下引起血压(BP)的振荡变化,适用于评估动态压力反射敏感性(BRS)。但是,关于这种方法的可靠性及其识别压力反射基本特性的能力知之甚少。在本研究中,我们寻求:1)评估从站到站方法评估BRS的可靠性,并将其与两种已建立的方法(Oxford方法和Valsalva机动)进行比较,以及2)检查从站到站方法的频率站立方法会影响磁滞。十六名健康参与者对每种方法进行了三项试验。对于以0.1和0.05 Hz进行的从站到站的方法,将BRS量化为积分响应(BRSint)以及对BP下降和上升的响应(分别为BRSdown和BRSup)。使用组内相关系数(ICC)评估重测信度。从坐姿到站立法,BRSint的ICC≥0.88,而与频率无关。在牛津法中,由去氧肾上腺素(PEGain)引起的血压升高的ICC为0.78,其余指标为<0.5。在从坐到站的方法中,所有参与者在0.1 Hz时都有明显的磁滞现象,但在0.05 Hz时没有磁滞现象。这些发现表明,从站到站的方法是一种统计上可靠的BRS评估工具,适用于压力反射滞后的检查。使用这种方法,我们证明了压力反射磁滞是一种频率相关的现象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号