The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor

机译:管电位对使用数字光刺激存储磷光传感器的牙周骨水平测量和主观图像质量的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objectives: The purpose of the present study was to determine the measurement accuracy and subjective image quality for periodontal disease diagnosis when using two X-ray tube voltages with a digital photostimulable storage phosphor sensor.Material and Methods: A digital photostimulable storage phosphor (PSP) sensor (Vistascan) and a multipulse X-ray generator (Prostyle Intra) with two tube voltages were used in this study. The front, premolar and molar region of two adult human cadaver skulls jaws were imaged using the X-ray tube at 63 kV and 70 kV, both at 8 mA and decreasing exposure times (160 ms, 120 ms and 80 ms). A standardized exposure protocol containing waxed occlusal keys and an aiming device ensured proper and reproducible beam alignment. Three observers assessed the digital radiographs for 31 selected periodontal bone loss sites. Radiographic measurements were compared to physical measurements (Standard). Subjective ratings of lamina dura, crater defect and furcation involvement visibility, contrast perception and bone quality were also performed.Results: Multiple regression equation of the variables kV and exposure time demonstrated no significant difference for the periodontal bone level measurements (P>0.05). In 90.3% and 96.7% of the measurements for 70 kV and 63 kV respectively, deviation was within 1 mm. The subjective ratings produced similar findings in terms of image quality for both tube voltages and the three exposure times.Conclusions: The results of the present study revealed that tube voltages of 63 kV and 70 kV provided similar accuracy and image quality for periodontal disease diagnosis.
机译:目的:本研究的目的是确定使用两个X射线管电压和数字光激发存储荧光粉传感器时牙周疾病诊断的测量精度和主观图像质量。材料和方法:数字光激发存储荧光粉(PSP)在这项研究中,使用了传感器(Vistascan)和具有两个电子管电压的多脉冲X射线发生器(Prostyle Intra)。使用X射线管在63 kV和70 kV电压下,分别在8 mA和减少的曝光时间(160 ms,120 ms和80 ms)下对两个成年人类尸体头骨下颌的前,前磨牙和磨牙区域成像。包含蜡质咬合钥匙和瞄准装置的标准化曝光协议可确保正确且可再现的光束对准。三名观察员评估了31个选定牙周骨丢失部位的数字X线照片。将射线照相测量值与物理测量值(标准)进行比较。结果:kV和暴露时间变量的多元回归方程对牙周骨水平的测量无显着性差异(P> 0.05)。 70 kV和63 kV的测量值分别为90.3%和96.7%,偏差在1 mm以内。主观评级在管电压和三个曝光时间的图像质量方面产生了相似的结果。结论:本研究的结果表明,63 kV和70 kV的管电压为牙周疾病诊断提供了相似的准确性和图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号