We report concentrations and isotopic compositions of He, Ne, and Ar measured with high spatial resolution along a radial traverse of a silicon carbide (SiC) quadrant of the Genesis mission concentrator target. The Ne isotopic composition maps instrumental fractionation as a function of radial position in the target: the maximum observed isotopic fractionation is approximately 33‰ per mass unit between the center and periphery. The Ne fluence is enhanced by a factor of 43 at the target center and decreases to 5.5 times at the periphery relative to the bulk solar wind fluence. Neon isotopic profiles measured along all four arms of the "gold cross" mount which held the quadrants in the concentrator target demonstrate that the concentrator target was symmetrically irradiated during operation as designed. We used implantation experiments of Ne into SiC and gold to quantify backscatter loss and isotopic fractionation and compared measurements with numerical simulations from the code "stopping and range of ions in matter." The ^(20)Ne fluence curve as a function of radial distance on the target may be used to construct concentration factors relative to bulk solar wind for accurate corrections for solar wind fluences of other light elements to be measured in the concentrator target. The Ne isotopic composition as a function of the radial distance in the SiC quadrant provides a correction for the instrumental mass-dependent isotopic fractionation by the concentrator and can be used to correct measured solar wind oxygen and nitrogen isotopic compositions to obtain bulk solar wind isotopic compositions.
机译:我们报告了沿创世纪任务集中器目标的碳化硅(SiC)象限的径向遍历以高空间分辨率测量的He,Ne和Ar的浓度和同位素组成。 Ne同位素组成将仪器分级映射为目标中径向位置的函数:观察到的最大同位素分级约为中心和外围之间每质量单位33‰。相对于整体太阳风能量密度,Ne能量密度在目标中心提高了43倍,而在外围降低到5.5倍。沿着“金十字”支架的所有四个臂(将象限保持在集中器靶中)测量的氖同位素剖面表明,在设计过程中,集中器靶受到了对称照射。我们使用了向SiC和金中注入Ne的实验来量化反向散射损耗和同位素分馏,并将测量结果与“物质中离子的停止和作用范围”代码的数值模拟进行了比较。作为目标上径向距离的函数的^(20)Ne能量密度曲线可用于构建相对于整体太阳风的集中因子,以精确校正要在集中器目标中测量的其他轻元素的太阳风力密度。 Ne同位素组成随SiC象限中径向距离的函数提供了对浓缩器对仪器的质量相关同位素分馏的校正,可用于校正测得的太阳风中的氧和氮同位素组成,以获得大量太阳风中的同位素组成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号