首页> 外文OA文献 >Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty
【2h】

Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty

机译:切片编码金属伪影校正和观角倾斜磁共振成像和传统数字射线照相的比较评价总髋关节置换术后慢性髋关节疼痛

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: The aims of this study were (1) to compare the areas of metal-induced artifacts and definition of periprosthetic structures between patients scanned with the slice-encoding metal artifact correction and view-angle tilting (SEMAC-VAT) turbo-spin-echo (TSE) prototype and those scanned with the standard TSE magnetic resonance (MR) sequences and (2) to further clarify the superiority of the SEMAC-VAT MR imaging technique at detecting lesions in patients after total hip arthroplasty (THA), compared with digital radiography (DR).Materials and methods: A total of 38 consecutive patients who underwent THA were referred to MR imaging at our institution. All patients suffered from chronic hip pain postoperatively. Twenty-three patients of the 38 were examined with a 1.5-T MR scanner using a SEMAC-VAT TSE prototype and standard TSE sequence, and the remaining 15 patients were examined with the same 1.5-T MR scanner, but using the SEMAC-VAT TSE prototype only. The traditional DR imaging was also performed for all patients. Two radiologists then independently measured the area of metal-induced artifacts and evaluated the definition of both the acetabular and femoral zones based on a three-point scale. Finally, the positive findings of chronic hip pain after THA based on SEMAC-VAT TSE MR imaging and traditional DR imaging were compared and analysed.Results: The areas of metal-induced artifacts were significantly smaller in the SEMAC-VAT TSE sequences than those in the standard TSE sequences for both the T1-weighted (p < 0.001) and T2-weighted (p < 0.001) turbo inversion recovery magnitude images. In addition, 28 patients showed a series of positive signs in the SEMAC-VAT images that were not observed in the traditional DR images.Conclusion: Compared with the standard TSE MR imaging, SEMAC-VAT MR imaging significantly reduces metal-induced artifacts and might successfully detect most positive signs missed in the traditional DR images.Translational potential of this article: The main objective of this research was to show that MR sequences from the SEMAC-VAT TSE prototype provide a significant advantage at detecting lesions in patients after THA because of the excellent soft-tissue resolution of the MR imaging. SEMAC-VAT MR can evaluate chronic hip pain after THA and determine the cause, which can help the clinician decide on whether a surgical revision is needed.
机译:目的:本研究的目的是(1),比较金属诱导的工件和患者扫描的患者的定义,与切片编码金属伪影校正和观角倾斜(SEMAC-VAT)涡轮旋转 - 与标准TSE磁共振(MR)序列扫描的回声(TSE)原型和那些扫描(2),以进一步阐明SEMAC-VAT MR成像技术的优越性在患有总髋关节置换术(THA)后检测患者的病变。数字射线照相(DR)。材料和方法:共有38名接受THA的患者被提交给我们机构的MR成像。所有患者术后患有慢性髋关节疼痛。使用SEMAC-VAT TSE原型和标准TSE序列使用1.5-T MR扫描仪检查38名患者,并使用相同的1.5-T MR扫描仪检查剩余的15名患者,但使用SEMAC-VAT仅限TSE原型。还对所有患者进行了传统的DR成像。然后,两个放射科医师独立地测量了金属诱导的伪影区域,并基于三点刻度评估髋臼和股骨区的定义。最后,基于Semac-Vat TSE MR成像和传统DR成像的THA后慢性髋关节疼痛的阳性结果进行了比较和分析。结果:SEMAC-VAT TSE序列中的金属诱导的伪影区域比那些在内用于T1加权(P <0.001)和T2加权(P <0.001)涡轮反转恢复幅度图像的标准TSE序列。此外,28名患者在传统的DR图像中未观察到的SEMAC-VAT图像中的一系列积极标志。结论:与标准TSE MR成像相比,SEMAC-VAT MR成像显着减少了金属诱导的伪影和可能成功地检测传统博士图像中错过的大多数积极迹象。本文的制定潜力:本研究的主要目标是表明,SEMAC-VAT TSE原型的MR序列在检测THA之后检测患者的病变是显着的优势优异的MR成像软组织分辨率。 SEMAC-VAT MR可以在THA之后评估慢性髋关节疼痛并确定原因,这可以帮助临床医生决定是否需要手术修订。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号