首页> 美国政府科技报告 >Rigid Pipe Proof Testing Under Excess Overfills with Varying Backfill Parameters. Section V (Volume 2) - Effective Densities Calculated from Interpolated, Unmodified, Measured Normal Tractions
【24h】

Rigid Pipe Proof Testing Under Excess Overfills with Varying Backfill Parameters. Section V (Volume 2) - Effective Densities Calculated from Interpolated, Unmodified, Measured Normal Tractions

机译:具有不同回填参数的过量溢流下的刚性管道防爆测试。第V节(第2卷) - 根据插值,未修改,测量的正常牵引计算的有效密度

获取原文

摘要

'Effective density' profiles were calculated from normal tractions interpolated between soil stressmeters at the outer periphery of the Cross Canyon, reinforced concrete culvert. 'Effective density' is the hypothetical density of an embankment material required to produce, under hydrostatic conditions, a measured soil stress under the measured overfill at the meter. Aside from the interpolations no adjustments have been made in the data. The normal tractions from which these 'densities' have been derived will not, in general, satisfy static equilibrium considerations in the pipe.