首页> 美国政府科技报告 >Comparison Between Shear Wave Ultrasonic Examination and Radiographic Examination of Some Austenitic Stainless Steel Pipe Welds
【24h】

Comparison Between Shear Wave Ultrasonic Examination and Radiographic Examination of Some Austenitic Stainless Steel Pipe Welds

机译:某些奥氏体不锈钢管焊缝剪切波超声波检测与射线检测的比较

获取原文

摘要

This paper compares the results of the ultrasonic and radiographic examinations of five austenitic pipe to pipe welds, which contained different types of intentional weld defects. Comparison between the results of the ultrasonic and radiographic examinations leads to the conclusion that neither method gives quite satisfactory results. Both methods missed some defects and the correlation between the results of the methods was not very good. In the ultrasonic examination the most difficult problem was the evaluation of the defects.