首页> 美国政府科技报告 >Orifice Plate Design Studies for a Multiple-Compartment, Ion-Exchange Column
【24h】

Orifice Plate Design Studies for a Multiple-Compartment, Ion-Exchange Column

机译:多室离子交换柱的孔板设计研究

获取原文

摘要

Preliminary studies by the Bureau of Mines were conducted to determine the feasibility of a multiple-compartment, ion-exchange (MCIX) column simulator for examining the effect of multiple-orifice plates in the column. A rectangular, five-orifice, three-compartment, MCIX simulator with a cross-sectional plate area of 0.66 sq ft was used for the investigation. Orifices with open areas of 1, 3, and 5 percent were used with various operating conditions. The study was separated into three separate sections: (1) solution flow effect, (2) fluidization effect, and (3) resin transfer effect. The solution flow and fluidization studies showed that for solution flow rates of about 3 gpm/sq ft, a 1-percent open area plate functioned best, while at solution flow rates of 9 and 15 gpm/sq ft, the best open areas were 3 and 5 percent, respectively.