首页> 美国政府科技报告 >Superfund Record of Decision (EPA Region 9): Intel Santa Clara III SuperfundSite, Santa Clara, CA. (First Remedial Action), September 1990
【24h】

Superfund Record of Decision (EPA Region 9): Intel Santa Clara III SuperfundSite, Santa Clara, CA. (First Remedial Action), September 1990

机译:超级基金决策记录(Epa第9区):英特尔圣克拉拉三世superfundsite,圣克拉拉,加利福尼亚州。 (第一次补救行动),1990年9月

获取原文

摘要

The Intel (Santa Clara III) site includes a plant that performs quality controltesting of chemicals and electrical testing of semiconductors in Santa Clara, Santa Clara County, California. The site is in a predominantly industrial area, and overlies a major ground regional source of ground water, the Santa Clara Valley ground water basin. In 1982, the State conducted a leak detection program, which identified VOC contamination in an onsite shallow aquifer. Possible sources for the contamination may include the accidental dumping of solvents into an acid neutralization tank, accidental spills near an above-ground solvent storage facility, and cleaning of solvent-contaminated pipes during plant construction. It has been determined that no onsite source is presently contributing to ground water contamination. Since 1985, Intel has been pumping and treating ground water using granular activated carbon as an Initial Remedial Measure (IRM). The Record of Decision (ROD) addresses a final solution for restoring ground water to its beneficial use. The primary contaminants of concern affecting the ground water are VOCs including TCE.