首页> 美国政府科技报告 >Fan Noise Reduction Achieved by Removing Tip Flow Irregularities Behind the Rotor - Forward Arc Test Configurations
【24h】

Fan Noise Reduction Achieved by Removing Tip Flow Irregularities Behind the Rotor - Forward Arc Test Configurations

机译:通过消除转子 - 前向电弧测试配置背后的尖端流不规则来实现风扇噪声降低

获取原文

摘要

The noise source caused by the interaction of the rotor tip flow irregularities (vortices and velocity defects) with the downstream stator vanes was studied. Fan flow was removed behind a 0.508 meter (20 in.) diameter model turbofan through an outer wall slot between the rotor and stator. Noise measurements were made with far-field microphones positioned in an arc about the fan inlet and with a pressure transducer in the duct behind the stator. Little tone noise reduction was observed in the forward arc during flow removal; possibly because the rotor-stator interaction noise did not propagate upstream through the rotor. Noise reductions were maded in the duct behind the stator and the largest decrease occurred with the first increment of flow removal. This result indicates that the rotor tip flow irregularity-stator interaction is as important a noise producing mechanism as the normally considered rotor wake-stator interaction.