首页> 美国政府科技报告 >Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor
【24h】

Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

机译:人字形凹槽转子上非接触式指形密封的初步测试结果

获取原文

摘要

Low leakage, non-contacting finger seals have potential to reduce gas turbine engine specific fuel consumption by 2 to 3 percent and to reduce direct operating costs by increasing the time between engine overhauls. A non-contacting finger seal with concentric lift-pads operating adjacent to a test rotor with herringbone grooves was statically tested at 300, 533, and 700 K inlet air temperatures at pressure differentials up to 576 kPa. Leakage flow factors were approximately 70 percent less than state-of-the-art labyrinth seals. Leakage rates are compared to first order predictions. Initial spin tests at 5000 rpm, 300 K inlet air temperature and pressure differentials to 241 kPa produced no measurable wear.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com