The measurement integrity of the NOVA 201 digital ultrasonic thickness gage (NOVAgage) was demonstrated by comparing the NOVA gage measurements to the thickness gage measurements, and determining the bias and uncertainty of the NOVA gage when measuring redesigned solid rocket motor (RSRM) hardware per engineering test plans (ETP). The NOVA gage was tested by three different operators on steel and aluminum RSRM hardware for wall thickness. The results show that the measurement bias is not consistent. The uncertainty of the bias is caused by the heterogeneous material properties of the RSRM components that influence the time of flight of ultrasonic waves. The measurement uncertainty inherent to the design and operation of the NOVA gage is less in comparison to the uncertainty of the bias. The total measurement uncertainty cannot be substantially reduced by taking more than one measurement. There is no correlation between bias and the surface finish range of this test unless 3-in-One oil is used as a couplant, in which case there appears to be a slight trend. There is no correlation between uncertainty and the surface finish range. The measurement uncertainty of the NOVA gage can be reduced using 3-in-One oil as a couplant.