首页> 美国政府科技报告 >Test beam performance of the CDF plug upgrade hadron calorimeter
【24h】

Test beam performance of the CDF plug upgrade hadron calorimeter

机译:测试光束性能的CDF插头升级强子热量计

获取原文

摘要

We report on the performance of the CDF End Plug Hadron Calorimeter in a test beam. The sampling calorimeter is constructed using 2 inch iron absorber plates and scintillator planes with wavelength shifting fibers for readout. The linearity and energy resolution of the calorimeter response to pions, and the transverse uniformity of the response to muons and pions are presented. The parameter e/h, representing the ratio of the electromagnetic to hadronic response, is extracted from the data.