Over 2000 photomultiplier tubes have been selected as the readout device of the upgrade CDF Endplug calorimeter, a scintillator tile sampling calorimeter with wave-shifter fiber readout. The specifications were set on various properties of the tubes for the electromagnetic and hadronic compartments and a series of rigorous tests were made on 2216 Hamamatsu R4125, 10-stage 19 mm diameter tubes with green-extended bialkali photocathode. On all of the test items, the distributions of the data were well clustered with minor tails, and the original specifications based on a small ensemble were well suited for rejecting the tails of the distributions. After rejecting 5.4% of the total, 960 tubes for electromagnetic and 864 tubes for hadronic compartments were allocated to projective towers based on their linear dynamic ranges. Tubes with greater linear ranges were assigned to larger pseudo-rapidity channels where greater single-tower energy deposits were expected. This paper describes how we selected the phototubes for our calorimeter and presents the results of the study we made.
机译:超过2000支光电倍增管已被选为升级版CDF Endplug热量计的读数设备,该设备是具有波型光纤读数的闪烁器瓦片采样热量计。对电磁室和强子室管的各种性能设定了规格,并在2216 Hamamatsu R4125,直径为10级,直径为19的带绿色扩展的双碱性光电阴极的管上进行了一系列严格的测试。在所有测试项目上,数据的分布都很好地聚在一起,并带有次要的尾部,并且基于小集合的原始规范非常适合拒绝分布的尾部。剔除总数的5.4%之后,根据其线性动态范围将960根电磁管和864强子室管分配给了投射塔。具有较大线性范围的管被分配给较大的伪快速通道,在该通道中预期会有更多的单塔能量沉积。本文介绍了如何选择量热计的光电管,并介绍了我们的研究结果。