首页> 外文期刊>IEEE Transactions on Nuclear Science >Performance of a prototype CMS hadron barrel calorimeter in a test beam
【24h】

Performance of a prototype CMS hadron barrel calorimeter in a test beam

机译:CMS强子管量热仪原型在测试光束中的性能

获取原文
获取原文并翻译 | 示例
           

摘要

We report on the performance of a prototype CMS Hadron Barrel Calorimeter (HCAL) module in a test beam. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. Placing a lead tungstate crystal electromagnetic calorimeter in front of HCAL affects the linearity and energy resolution of the combined system to hadrons. The data are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation.
机译:我们报告了CMS强子管量热仪(HCAL)原型在测试光束中的性能。原型量热仪使用带有波长偏移光纤的铜吸收板和闪烁体砖进行读数。在HCAL前面放置钨酸铅晶体电磁热量计会影响组合系统对强子的线性和能量分辨率。该数据用于优化总吸收器深度,采样频率和纵向读数分段的选择。