首页> 美国政府科技报告 >Plasma Cleaning, End-of-Process Detection
【24h】

Plasma Cleaning, End-of-Process Detection

机译:等离子清洗,工艺结束检测

获取原文

摘要

Activated gas plasma is being used extensively to remove trace organic contamination from electromechanical components prior to final assembly. Optical emission techniques are being used throughout the electronics industry to determine end-points of plasma processes for removing large amounts of photo-resist. The application of these techniques to detect the removal of trace organic residues was shown to be possible using a borrowed process monitor. Removal of organic contamination as low as 5 mg total was detected in an oxygen plasma. Auger analysis confirmed the cleanliness levels indicated by the end-point detector tested. The simplicity of this type of process monitor lends itself to production line use for the plasma cleaning of various parts and batch sizes. The monitoring of argon plasma cleaning processes using optical emission techniques has also been investigated. (ERA citation 05:026149)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号