首页> 美国政府科技报告 >Develop and Test Fuel Cell Powered on-Site Integrated Total Energy Systems. Phase III, Full-Scale Power Plant Development. 11TH Quarterly Report, August-October 1983
【24h】

Develop and Test Fuel Cell Powered on-Site Integrated Total Energy Systems. Phase III, Full-Scale Power Plant Development. 11TH Quarterly Report, August-October 1983

机译:开发和测试燃料电池供电的现场集成总能源系统。第三阶段,全面发电厂开发。 1983年8月至10月第11季度报告

获取原文

摘要

On-going test experience with a 5kW methanol-air integrated system is described. Long-term successful operation of a semi-automated electrolyte-replenishment system and non-metallic cooling plates was sustained in a 24-cell, two-ft exp 2 (4kW) stack. Single-cell test results for two developmental cathode catalysts are reported. Corrosion-protection efforts for metallic current-collecting plates are described. (ERA citation 09:016707)