首页> 美国政府科技报告 >Recent Developments in Ultrasonic Probes Working Up to 180 Deg C for the Inspection of the Superphenix Fast Breeder Reactor.
【24h】

Recent Developments in Ultrasonic Probes Working Up to 180 Deg C for the Inspection of the Superphenix Fast Breeder Reactor.

机译:超高速探头在180℃下工作以检测超级快速增殖反应堆的最新进展。

获取原文

摘要

The main and safety vessels of SUPERPHENIX were designed to allow In-Service-Inspections. The remote controlled device MIR was developed for this purpose. The ultrasonic examination has required the development of all new focused transducers fitted with severe operating conditions prevailing in the intervessels interval: nitrogen gas at 180 deg C. We give a list of problems to be resolved and technological solutions which were found. Measurements of acoustical properties on actual probes are compared with theoretical values. We produce some examples obtained in actual conditions which show the detection of reference reflectors located in welds at various depth, with various disalignments against focus beam. Inspite of the severe environment and the perturbations caused by the austenitic welds, the I.S.I of SPX1 using high temperatures transducers is possible with a good spatial resolution and signal to noise ratio. (ERA citation 13:040721)