首页> 美国政府科技报告 >Residual Chlorine Removal Method to Allow Drinking Water Monitoring by Biological Early Warning Systems
【24h】

Residual Chlorine Removal Method to Allow Drinking Water Monitoring by Biological Early Warning Systems

机译:生物预警系统监测饮用水的残余氯去除方法

获取原文

摘要

Aquatic biomonitors can provide continuous, real-time monitoring for toxicity in source water supplies, but they cannot be used to directly monitor chlorinated drinking waters because of aquatic organism sensitivity to residual chlorine. The threshold for a toxicity alarm by a biomonitor using bluegills (Lepomis macrochirus) was between 0.015 and 0.066 mg/L total residual chlorine (TRC). A portable dechlorinator that injected 6 mg/L sodium bisulfite into water containing 1.5 to 2.0 mg/L TRC was effective in removing TRC-related toxicity during a nine month evaluation at a water treatment plant. Three biomonitor alarms that occurred were not caused by dechlorinator malfunctions. In one-hour laboratory exposures to sodium bisulfite alone, the biomonitor did not respond until concentrations exceeded 48 mg/L. This study demonstrated the feasibility of using a biomonitor in conjunction with a portable dechlorinator for continuous monitoring of chlorinated drinking waters. Future studies should evaluate dechlorinator suitability in waters with total organic carbon levels exceeding 2 mg/L or that have been disinfected with chloramines.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号