首页> 美国政府科技报告 >Circuitry and Operation of an X-Band Interferometer for Shock-Tube Measurements Using the Dielectric Slab Approximation
【24h】

Circuitry and Operation of an X-Band Interferometer for Shock-Tube Measurements Using the Dielectric Slab Approximation

机译:使用介质板近似的用于冲击管测量的X波段干涉仪的电路和操作

获取原文

摘要

The experimental methods and equipment used in analyzing transient shock-generated plasmas by X-band microwave interaction techniques are presented in considerable detail. A transmission technique (for electron densities of 10 to the 10th power to 10 to the 13th power electrons/cc) and a reflection technique (extending the range to about 10 to the 16th power electrons/cc) are discussed with respect to the construction and adjustment of the microwave apparatus and the required data reduction. An evaluation of the experimental errors due to the electronic equipment and data reduction procedure is given. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号