首页> 美国政府科技报告 >Energy Factors and Temperature Distribution in Insulated Built-Up Roofs
【24h】

Energy Factors and Temperature Distribution in Insulated Built-Up Roofs

机译:绝缘组合屋盖的能量因子和温度分布

获取原文

摘要

Surface temperatures of 4-ply built-up roofs insulated with (1) 1 inch of perlite (R = 2.8) and 2-1/2 inches of urethane (R = 19.2) and (2) 1 inch of urethane (R = 7.1) and 1-7/8 inches of glass fiber (R = 7.7) are presented. Energy factors are shown in terms of temperature-time areas defined as solar heat response, cooling (heating) required, radiative cooling, and insulation efficiency. Results indicate that for a black surface, solar heat response is significantly higher in the roof portion with the higher R-value. Solar heat response is directly affected by color of surfacing; lowest to highest values were found with white, white gravel, gray gravel, aluminum-gray, and black. Recommendations are given for reducing surface temperatures of insulated built-up roofs. (Author)