首页> 美国政府科技报告 >Gas Chromatographic Method for Direct Measurement of Trace Levels of Volatile Aliphatic Amines in Aqueous Samples.
【24h】

Gas Chromatographic Method for Direct Measurement of Trace Levels of Volatile Aliphatic Amines in Aqueous Samples.

机译:气相色谱法直接测定水样中痕量挥发性脂肪胺。

获取原文

摘要

Volatile aliphatic amines in environmental samples are generally determined by gas chromatographic methods. Although these methods are the most sensitive, there significant interferences when trace levels are to be measured in complex aqueous samples. A gas chromatographic method using low oven temperature (30 C) and a packing consisting of 10% Carbowax 20M with 2% KOH an 80/100 Chromosorb W AW was developed to minimize these problems. The method has been used to measure these amine in bacterial broth cultures from direct, unfiltered injections of the medium with little or no interface by other compounds.