首页> 美国政府科技报告 >Inward Contaminant Leakage Tests of the S-Tron Corporation Emergency EscapeBreathing Device. Phase 1. Tests of the Original Design. Phase 2. Tests with the Redesigned Neck Seal
【24h】

Inward Contaminant Leakage Tests of the S-Tron Corporation Emergency EscapeBreathing Device. Phase 1. Tests of the Original Design. Phase 2. Tests with the Redesigned Neck Seal

机译:s-Tron公司紧急逃生呼吸装置的内向污染物泄漏测试。阶段1.原始设计的测试。阶段2.使用重新设计的颈部密封进行测试

获取原文

摘要

At the request of S-Tron Corporation, to support their contract with the U.S.Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur hexafluoride (SF6) challenge was used to determine contaminant leakage; oxygen and carbon dioxide levels, as well as temperature readings, were also obtained. Eight successful tests were conducted with the original neck seal design first used by Scott Aviation in their Crewmember Protective Breathing Equipment, four additional tests were conducted with a proprietary new neck seal designed by S-Tron. The EEBD all performed within test limits. Emergency escape breathing device (EEBD) Contaminant Leakage U.S. Navy S-TRON.