A comparison of the MicroCount Digital System to plate count and membrane filtration methods for the enumeration of microorganisms in water for pharmaceutical purposes.

机译:MicroCount数字系统与平板计数和膜过滤方法的比较,用于计数水中的微生物,用于制药目的。

获取原文
获取原文并翻译 | 示例
           

摘要

The enumeration of microorganisms in water for pharmaceutical purposes using the MicroCount Digital System (Millipore Corporation, Bedford, MA) was compared to the USP-recommended Pour Plate and Membrane Filtration Count methods. A study, using a pure culture of Buckholderia cepacia, ATCC#25416, showed that the accuracy, precision, reproducibility and linearity of the MicroCount ATP Bioluminescence System was equivalent to or better than the traditional methods. When the MicroCount System was used to monitor purified water and water for injection taps in a pharmaceutical plant over a month, comparable counts to the traditional methods were obtained within 24 hours compared to 48 to 72 hours with the other methods. The effectiveness of the memory device used for the isolation of colonies for characterization was demonstrated by comparing the number and pattern of the positive wells in the MicroCount plates with the isolation of colonies on the microbial count agar plates. The recovery on agar plates, although slightly higher, was not statistically different to the MicroCount plates. The predominated microorganisms isolated using all three methods were Ralstonia pickettii, Bacillus sphaericus, Stenotrophomonas maltophia, and a Staphylococcus species.
机译:使用MicroCount Digital System(Millipore公司,贝德福德,马萨诸塞州)将制药用水中的微生物计数与USP推荐的倾倒板和膜过滤计数方法进行了比较。一项使用纯西洋参(Buckholderia cepacia)培养物ATCC#25416的研究表明,MicroCount ATP生物发光系统的准确性,精密度,可再现性和线性与传统方法相当或更好。当使用MicroCount系统监测纯净水和制药厂一个月内的注射用水时,在24小时内可获得与传统方法相当的计数,而其他方法则为48至72小时。通过比较MicroCount平板上阳性孔的数量和样式与微生物计数琼脂平板上菌落的分离,证明了用于分离菌落进行表征的存储设备的有效性。琼脂平板上的回收率虽然略高,但与MicroCount平板没有统计学差异。使用这三种方法分离出的主要微生物是拟南芥,球形芽孢杆菌,嗜麦芽窄食单胞菌和葡萄球菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号