首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Diagnostic value of nitrate stimulated tilt testing without preceding passive tilt in patients with suspected vasovagal syncope and a healthy control group.
【24h】

Diagnostic value of nitrate stimulated tilt testing without preceding passive tilt in patients with suspected vasovagal syncope and a healthy control group.

机译:硝酸盐刺激的倾斜试验在未怀疑有被动迷走性晕厥的患者和健康对照组中的诊断价值。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: The contribution of the passive tilt phase, in a combined nitrate stimulated tilt protocol may be low yielding. In order to develop a shortened, and thus easier to perform test, we investigated the optimal duration of a nitrate tilt protocol without a preceding passive phase. METHODS: Thirty-eight consecutive patients (18F/20M; mean age 46 +/- 16) with clinically suspected vasovagal syncope and 31 control subjects (15F/16M; mean age 40 +/- 18) were tested. The subjects were tilted to 70 degrees for a maximum period of 30 minutes, and sublingual nitroglycerin 0.4 mg spray was administrated directly after attaining erect posture. Receiver operator characteristics (ROC) analysis was done to determine the optimal test duration. RESULTS: In the patient group 31 (82%) and in controls 5 (16%) had a positive test. Sensitivity, specificity, and accuracy at test end were 82, 84, and 83%, respectively. ROC analysis revealed that a maximum accuracy of 83% was attained at 14 minutes, with a sensitivity and specificity of 79 and 87%, respectively. CONCLUSION: Nitrate stimulated tilt testing, without a preceding passive tilt phase, and limited to a test duration of 15 minutes, provides an accurate, sensitive, and specific method to provoke vasovagal reactions in subjects with clinically suspected vasovagal syncope.
机译:背景:在组合硝酸盐刺激的倾斜方案中,被动倾斜相的贡献可能较低。为了开发缩短的,因此更易于执行的测试,我们研究了硝酸盐倾斜方案的最佳持续时间,而无需事先进行被动阶段。方法:测试了38例临床怀疑为血管迷走性晕厥的连续患者(18F / 20M;平均年龄46 +/- 16)和31名对照受试者(15F / 16M;平均年龄40 +/- 18)。将受试者倾斜至70度,最长持续30分钟,在达到直立姿势后立即施用舌下硝化甘油0.4 mg喷雾剂。进行接收者操作员特征(ROC)分析以确定最佳测试持续时间。结果:患者组31例(82%)和对照组5例(16%)检测为阳性。测试结束时的敏感性,特异性和准确性分别为82%,84%和83%。 ROC分析显示,在14分钟时可达到83%的最高准确度,灵敏度和特异性分别为79%和87%。结论:硝酸盐刺激的倾斜试验,没有之前的被动倾斜阶段,并且限于15分钟的测试持续时间,提供了一种准确,灵敏和特异的方法,可在患有临床怀疑为血管迷走性晕厥的受试者中引起血管迷走反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号