首页> 外文期刊>Steel & Composite Structures: An International Journal >Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders
【24h】

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

机译:高强螺栓连接钢混凝土组合梁的受弯性能试验研究

获取原文
获取原文并翻译 | 示例
       

摘要

In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain arc discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.
机译:在本文中,对高强度钢(HSS)螺柱连接的钢-混凝土组合(SCC)梁进行了实验研究,以了解剪切连接器密度对其弯曲行为的影响。通过改变剪切跨度中的双头螺栓连接器数量,将SCC大梁样本设计为具有三种不同的剪切能力(100%,85%和70%)。在单调/准静态载荷下测试了三个SCC梁样本,而在简单支撑的最终条件下,对三个相似的梁样本进行了不可逆循环载荷。讨论了铸造试样,实验装置和测试方法,用于测量挠度,界面滑移和应变弧的仪器的细节。发现为全剪切能力设计的SCC梁试样在超过极限载荷能力的25%的载荷下表现出界面滑移。剪切连接度较小的试样在滑移开始时显示较低的载荷值。所有HSS螺柱连接的SCC箱梁样品都具有很好的延展性。观察到,HSS螺柱连接的SCC梁的极限抗弯矩和延性都会降低,而螺柱剪力连接器密度会降低。根据分析,表明高强度双头螺栓连接器在抵抗界面力方面的有效性的效率因子估计为0.8。破坏模式主要是通过双头螺栓连接器断裂导致的弯曲,其特征是在纯弯曲区域顶部的混凝土发生弯曲开裂和破碎。在接近破坏的载荷下,也观察到钢梁顶部法兰的局部屈曲,这受螺栓间距和轧制钢型材顶部法兰厚度的影响。建议之一是将极限载荷能力限制为截面塑性矩能力的1.5倍,以使峰值载荷后的减小量保持在极限范围内。单调试验的载荷-挠度行为与循环试验的载荷-挠度曲线的包络线比较好。从实验研究得出的结论是,在给定载荷下,使用HSS螺柱会减少其数量,这在大跨度的情况下是有利的。在破坏阶段观察到轧制部分的顶部法兰弯曲。建议在顶部法兰中设置唇缘,以避免这种弯曲。如果跨度较长,则可以使用通常的组合截面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号