BACKGROUND: Our objective was to compare the performance of laparoscopic tasks by surgeons using standard laparoscopic instruments and two surgical robotic systems. METHODS: Eighteen surgeons performed tasks in a training box using three different instrument systems: standard laparoscopic instruments, the Zeus Robotic Surgical System, and the da Vinci Surgical System. Basic tasks included running a 100-cm rope, placing beads onto pins, and dropping cotton peanuts into cylinders; fine tasks included intracorporeal knot tying and running stitches with 4-0, 6-0, and 7-0 sutures. Time (in seconds) required and precision (number of errors) in performing each task were recorded. Analysis of variance with pair-wise comparisons using the Bonferroni method and Friedman's nonparametric test were used for statistical analysis. RESULTS: Standard instruments performed significantly faster than either robotic system on the rope and bead tasks (p <0.05), whereas da Vinci performed significantly faster than Zeus in all three basic tasks (p <0.05). No significant difference in precision was found between standard instruments and the robotic systems on any of the basic tasks. Knot-tying and running-suture time were similar between standard instruments and da Vinci, which were significantly faster than Zeus (p <0.05) for all suture sizes. The robotic systems were similar in precision for fine suturing tasks and were significantly more precise in knot tying (Zeus and da Vinci) and running sutures (da Vinci) than standard instruments (p <0.05). CONCLUSIONS: Basic laparoscopic task performance is generally faster and as precise using standard instruments compared to either robotic system. In performing fine tasks, neither robotic system is faster than standard instruments, although they may offer some advantage in precision.
机译:背景:我们的目的是比较外科医生使用标准腹腔镜仪器和两个外科手术机器人系统进行腹腔镜手术的性能。方法:十八名外科医生在训练箱中使用三种不同的仪器系统执行任务:标准腹腔镜仪器,宙斯机器人手术系统和达芬奇手术系统。基本任务包括运行100厘米长的绳索,将珠子放在大头针上以及将棉花花生放入圆柱体中。优良的任务包括体内打结和用4-0、6-0和7-0缝线缝合。记录所需的时间(以秒为单位)和执行每个任务的精度(错误数量)。使用Bonferroni方法和弗里德曼非参数检验进行成对比较的方差分析用于统计分析。结果:标准仪器在绳索和珠子任务上的执行速度明显优于机器人系统(p <0.05),而达芬奇在所有三个基本任务上的执行速度均显着高于Zeus(p <0.05)。在任何基本任务上,标准仪器和机器人系统之间的精度均无明显差异。在标准器械和达芬奇之间,打结和缝合时间相似,在所有缝合尺寸下,其结扎速度均显着高于宙斯(p <0.05)。机器人系统在精细缝合任务上的精度相似,并且在打结(Zeus和da Vinci)和缝合线(da Vinci)方面比标准仪器精确得多(p <0.05)。结论:与任一机器人系统相比,使用标准仪器的基本腹腔镜任务性能通常更快,更精确。在执行精细任务时,虽然它们在精度方面可能会提供一些优势,但是两种机器人系统都不比标准仪器快。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号