首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Comparative study of trace element contents in human full-term placenta and fetal membranes by total reflection X-ray fluorescence
【24h】

Comparative study of trace element contents in human full-term placenta and fetal membranes by total reflection X-ray fluorescence

机译:全反射X射线荧光对人足月胎盘和胎膜中微量元素含量的比较研究

获取原文
获取原文并翻译 | 示例

摘要

The total reflection X-ray fluorescence (TXRF) method was applied to study the influence of environmental pollution on the contents of trace elements in human full-term placenta and fetal membranes. The samples were collected from the donors living in two regions characterised by different levels of environmental pollution. In this comparative study, based on relatively large (approx 100) populations, the concentrations of approximately 20 trace elements (P-Pb) were determined in the samples. In particular, the paper discusses the role of 'truncation' of measured concentration distribution by the detection limit of the TXRF method in context of comparative studies. First, the importance of the developed method of reconstruction of original concentration distribution, to derive the correct concentrations of trace elements, is described and demonstrated and, second, the statistical tests, which can be used to compare the truncated, or reconstructed, concentration distributions are discussed. Finally, the statistically significant differences of trace element concentrations found in both populations are presented and summarised.
机译:采用全反射X射线荧光(TXRF)方法研究环境污染对人体足月胎盘和胎膜中微量元素含量的影响。样品是从生活在两个地区的捐助者那里收集的,这些捐助者的环境污染水平不同。在此比较研究中,基于相对较大的种群(约100个),在样品中确定了约20种微量元素(P-Pb)的浓度。特别是,本文在比较研究中讨论了通过TXRF方法的检出限来“截断”所测浓度分布的作用。首先,描述并证明了开发原始浓度分布重建方法的重要性,以得出痕量元素的正确浓度;其次,统计测试可用于比较截短或重建的浓度分布。讨论。最后,介绍并总结了在两个种群中发现的微量元素浓度的统计显着性差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号