A simple, rapid and accurate spectrophotometric method for the determination of antibiotic drugs, flucloxacillin (Fluclox) and dicloxacillin (Diclox), in pure form and different pharmaceutical preparations has been developed. The charge transfer (CT) reactions between Fluclox and Diclox as electron donors and 7,7,8,8-tetracyanoquinodimethane (TCNQ) and tetracyanoethylene (TCNE) as pi-acceptors to give highly coloured complex species have been spectrophotometrically studied. The optimum experimental conditions for these CT reactions have been studied carefully. Beer's law is obeyed over the concentration ranges of 4-180 mu g mL(-1) and 4-70 mu g mL(-1) for Fluclox and Diclox drugs using TCNQ and TCNE reagents, respectively. The Sandell sensitivities (S) are found to be 0.016-0.035 mu g cm(-2) and 0.011-0.016 mu g cm(-2) for Fluclox and Diclox, respectively, which indicate the high sensitivity of the proposed method. The relative standard deviations (R.S.D.: 0.08-0.49 and 0.15-0.80) for the determination of Fluclox and (R.S.D.: 0.05-0.75 and 0.13-0.75) for Diclox were obtained for four to six replicates using TCNQ and TCNE reagents, respectively, refer to the high accuracy and precision of the proposed method. These results are also confirmed by the between-day precision and the percent recovery of 99.90-100.1 and 99.60-100.4 for Fluclox and 99.90-100.5 and 99.40-100.1 for Diclox using TNCQ and TCNE reagents, respectively. The results obtained for the two reagents are comparable with those obtained by the official method. (c) 2005 Elsevier B.V. All rights reserved.
机译:已开发出一种简单,快速,准确的分光光度法,用于测定纯净形式和不同药物制剂的抗生素药物氟氯西林(Fluclox)和双氯西林(Diclox)。分光光度法研究了Fluclox和Diclox作为电子供体与7,7,8,8-四氰基喹二甲烷(TCNQ)和四氰基乙烯(TCNE)作为pi受体之间的电荷转移(CT)反应,从而得到了高度着色的复合物。已经仔细研究了这些CT反应的最佳实验条件。使用TCNQ和TCNE试剂分别对Fluclox和Diclox药物在4-180μg mL(-1)和4-70μgmL(-1)的浓度范围内遵守比尔定律。发现对Fluclox和Diclox的Sandell灵敏度(S)分别为0.016-0.035μg cm(-2)和0.011-0.016μg cm(-2),表明该方法具有很高的灵敏度。使用TCNQ和TCNE试剂分别进行四到六次重复测定时,测定Fluclox的相对标准偏差(RSD:0.08-0.49和0.15-0.80)和Diclox的相对标准偏差(RSD:0.05-0.75和0.13-0.75)。提出的方法的高精度和高精度。这些结果也通过使用TNCQ和TCNE试剂对Fluclox的日间精密度和99.90-100.1和99.60-100.4的百分回收率以及对Diclox的99.90-100.5和99.40-100.1的百分回收率得到了证实。两种试剂获得的结果与通过官方方法获得的结果相当。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号