首页> 外文期刊>Sportverletzung Sportschaden: Organ der Gesellschaft fu?r Orthopa?disch-Traumatologische Sportmedizin >Visualisation of bioabsorbable suture anchors with digital projection radiography and magnetic resonance imaging [Visualisierung bioresorbierbarer Fadenanker-Implantate mit digitaler Projektionsradiografie und Magnetresonanztomografie]
【24h】

Visualisation of bioabsorbable suture anchors with digital projection radiography and magnetic resonance imaging [Visualisierung bioresorbierbarer Fadenanker-Implantate mit digitaler Projektionsradiografie und Magnetresonanztomografie]

机译:用数字投影射线照相术和磁共振成像可视化可生物吸收的缝合锚钉[通过数字投影射线照相术和磁共振层析成像可视化可生物吸收的缝合锚钉]

获取原文
获取原文并翻译 | 示例
       

摘要

Background: During the last few years bioabsorbable suture anchors have become widely established along side metallic suture anchors in orthopaedic surgery. However, there are still some difficulties in evaluating the postoperative situation after implanting bioabsorbable suture anchors. The aim of this study was to examine the visualisation of bioabsorbable suture anchors with digital projection radiography and magnetic resonance imaging. Materials and Methods: Ten Mitek-Anchor-Panalok suture anchors made of polylactic acid were implanted in an ex-vivo animal study design. After implantation the specimens were examined with digital projection radiography and MRI. The analysis was performed with regard to the bony defects and the anchor material itself. Results: With digital projection radiography and MRI, it was possible to detect the bony defects after implantation of the anchors. The anchor material could not be visualised. Conclusion: The results of this study demonstrate that neither digital projection radiography nor MRI is well suited for the detection of the bioabsorbable suture anchors in the postoperative situation. Whereas the bony defects can be well described, the anchors cannot be directly visualised. The visualisation of bioabsorbable anchors remains a clinical problem in orthopaedic surgery.
机译:背景:在过去的几年中,在骨科手术中,沿侧面金属缝合线锚钉广泛使用了可生物吸收的缝合线锚钉。但是,在植入生物可吸收缝合锚钉后评估术后情况仍然存在一些困难。这项研究的目的是通过数字投影射线照相术和磁共振成像检查生物可吸收缝合锚钉的可视化。材料和方法:将十只由聚乳酸制成的Mitek-Anchor-Panalok缝合锚钉植入离体动物研究设计中。植入后,用数字投影射线照相术和MRI检查标本。针对骨缺损和锚固材料本身进行了分析。结果:利用数字投影射线照相术和MRI,可以在植入锚钉后检测出骨缺损。锚材料无法显示。结论:这项研究的结果表明,数字投影射线照相术或MRI都不适合在术后情况下检测可生物吸收的缝合锚钉。尽管可以很好地描述骨缺损,但无法直接看到锚钉。生物可吸收锚的可视化仍然是整形外科的临床问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号