首页> 外文期刊>Spine >Quantitative evaluation of the location of the vertebral artery in relation to the transverse foramen in the lower cervical spine.
【24h】

Quantitative evaluation of the location of the vertebral artery in relation to the transverse foramen in the lower cervical spine.

机译:定量评估下颈椎相对于横向孔的椎动脉位置。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: This study assessed the relationship of the vertebral artery and the transverse foramens in the lower cervical spine by computer tomographic angiography (CTA) measurements. OBJECTIVE: To study the location and the size of the vertebral artery in relation to the transverse foramens in the lower cervical spine. SUMMARY OF BACKGROUND DATA: Although many transverse foramen violations had been reported during pedicle screw insertion, the vertebral artery injury seems not as much as expected. The location and size of the vertebral artery in relation to the transverse foramen in the lower cervical spine is not very clear until now. METHODS: Fifty patients were selected in our study group. Several parameters were measured on the CTA axial imagines of C3-C7, including the maximal width (W) and the maximal height (H) of transverse foramen, the diameter of vertebral artery (AL), the shortest distance between the vertebral artery and the border of transverse foramen medial (M), lateral (L), anterior (A) and posterior (P), the shortest distance between the vertebral artery and pedicle (h), the area of vertebral artery (AVA) and transverse foramen (AF), and the ratio between AVA and AF (AVA/AF). RESULTS: W, H, and AF increase from C3-C6. M is shorter than L at all measurements. A is shorter than P at C3, C4, and C5, a little bit longer than P at C6 on the contrary. The shortest distance between vertebral artery and pedicle (h) vary from C3-C7, the shortest 0.5 +/- 0.2 mm at C3, the longest 7.3 +/- 2.7 mm at C7. AVA/AF decrease from C3-C6, 35.7 +/- 15.7% at C3 and 27.4 +/- 12.8% at C6. CONCLUSION: Vertebral artery is in the medial part of transverse foramen. There is a relative "abundance space" for vertebral artery in transverse foramen.
机译:研究设计:这项研究通过计算机断层血管造影(CTA)测量评估了下颈椎椎动脉和横向孔的关系。目的:研究下颈椎横孔相对于椎动脉的位置和大小。背景数据摘要:尽管在椎弓根螺钉插入过程中已报告了许多侵犯横向孔的情况,但椎动脉损伤似乎不如预期的多。到目前为止,下颈椎中椎动脉相对于横向孔的位置和大小还不清楚。方法:在我们的研究组中选择了五十名患者。在C3-C7的CTA轴向想象中测量了多个参数,包括横向孔的最大宽度(W)和最大高度(H),椎动脉的直径(AL),椎动脉之间的最短距离横孔内侧(M),外侧(L),前(A)和后(P)的边界,椎动脉和椎弓根之间的最短距离(h),椎动脉(AVA)和横孔(AF)的面积),以及AVA与AF之间的比率(AVA / AF)。结果:W,H和AF从C3-C6开始增加。在所有测量中,M都比L短。在C3,C4和C5处,A短于P,相反,在C6处,A短于P。椎动脉和椎弓根之间的最短距离(h)在C3-C7之间变化,在C3处最短0.5 +/- 0.2 mm,在C7处最长7.3 +/- 2.7 mm。 AVA / AF从C3-C6下降,在C3下降35.7 +/- 15.7%,在C6下降27.4 +/- 12.8%。结论:椎动脉位于横孔的内侧。在横向孔中,椎动脉有一个相对的“丰富空间”。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号