首页> 外文期刊>Spinal cord: the official journal of the International Medical Society of Paraplegia >Energy expenditure during walking with weight-bearing control (WBC) orthosis in thoracic level of paraplegic patients.
【24h】

Energy expenditure during walking with weight-bearing control (WBC) orthosis in thoracic level of paraplegic patients.

机译:截瘫患者胸部水平负重控制(WBC)矫形器行走时的能量消耗。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN:: Comparative study of the effectiveness of walking exercise with a newly developed gait orthosis, the weight-bearing control (WBC) orthosis, for thoracic level of paraplegic patients. OBJECTIVES:: To test its feasibility as a rehabilitation alternative for paraplegic patients, the energy consumption and cost during walking with WBC were calculated and compared with the values of conventional orthoses given in previous reports. SETTING:: National Rehabilitation Center for the Disabled, Japan. METHODS:: Four paraplegic patients with traumatic spinal cord injuries ranging from T8 to T12 participated. Experiments were conducted after 3 months of the orthotic gait training with WBC. The cardiorespiratory parameters were continuously measured at rest and during walking with a telemetric device. The steady-state value of the oxygen uptake (V(O(2))), heart rate (HR), the energy consumption (J/kg/s) and energy cost (J/kg/m) were calculated. RESULTS:: The average walking speed was 19.0+/-2.58 m/min. The steady-state value of the V(O(2)) and HR were 16.08+/-1.93 ml/kg and 147.3+/-10.94 b/min, respectively. The energy cost during orthotic walking tended to be better than the values of conventional orthoses, whereas the energy consumption was almost similar. CONCLUSION:: WBC enables thoracic level of paraplegic patients to walk at relatively higher speed than conventional orthoses under similar energy expenditure. The special devices equipped with WBC are therefore considered to lead to improvement of the energy cost of walking. The physical intensity presumed by cardiorespiratory responses during walking with WBC is suited to promote their aerobic capacity. Therefore, it is concluded that the WBC orthosis could be an effective alternative in rehabilitation for thoracic level of paraplegic patients.Spinal Cord (2003) 41, 506-510. doi:10.1038/sj.sc.3101494
机译:研究设计:一项新开发的步态矫形器(举重控制(WBC)矫形器)对截瘫患者胸廓水平的步行运动效果的比较研究。目的:为了测试其作为截瘫患者康复替代方案的可行性,计算了WBC行走过程中的能量消耗和成本,并将其与先前报告中给出的传统矫形器的值进行了比较。地点:日本国家残疾人康复中心。方法:四名截瘫患者均患有脊髓损伤,范围从T8到T12。用WBC进行3个月的矫形步态训练后进行了实验。在静止和步行期间使用遥测设备连续测量心肺参数。计算出摄氧量(V(O(2))),心率(HR),能量消耗(J / kg / s)和能量成本(J / kg / m)的稳态值。结果::平均步行速度为19.0 +/- 2.58 m / min。 V(O(2))和HR的稳态值分别为16.08 +/- 1.93 ml / kg和147.3 +/- 10.94 b / min。矫形步行过程中的能量成本往往比传统的矫形器更好,而能量消耗几乎相似。结论:WBC使截瘫患者的胸部水平在类似的能量消耗下以比传统矫形器更高的速度行走。因此,配备有WBC的特殊设备被认为可以改善步行的能源成本。由WBC行走期间心肺反应所推测的身体强度适合提高其有氧运动能力。因此,得出的结论是,WBC矫形器可能是截瘫患者胸部水平康复的有效替代方法。SpinalCord(2003)41,506-510。 doi:10.1038 / sj.sc.3101494

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号