In this paper, we describe a compact, non-destructive calibration setup using a fiber optic Fabry-Perot interferometric (FOFPI) displacement sensor and a circular, mono-morphic piezoelectric plate actuator. The piezoelectric actuator strains the sensor under calibration, and the FOFPI measures the resulting displacement and strain. Using a linear fitting equation that relates the fractional change in sensor output and the measured strain, the strain gauge factor (SGF) is determined. For demonstration purposes, the setup is used to determine the strain gauge factor of a resistive strain gauge (RSG). The measured SGF of the RSG was found to be within 2% of the manufacturer's stated value.
机译:在本文中,我们描述了使用光纤法布里-珀罗干涉仪(FOFPI)位移传感器和圆形单态压电板执行器的紧凑,无损校准设置。压电致动器在校准状态下使传感器变形,而FOFPI测量所产生的位移和变形。使用将传感器输出的分数变化与测得的应变相关联的线性拟合方程,可以确定应变仪系数(SGF)。出于演示目的,该设置用于确定电阻应变仪(RSG)的应变仪系数。发现测得的RSG的SGF在制造商规定值的2%以内。