This report presents a new compensation method for distortions related to dead time, caused by B6-inverters with pulse-width-modulated output voltages. In spite of low sampling rates, the new method of compensation is effective at all ranges of rotation speed up to the field weakening region. No additional hardware is required for its implementation. The effectiveness of the new method has been shown experimentally. A description of the relevant distortions is given first to provide a basis for the development. This considers the field weakening region, and offers an illustrative method of quantifying the distortions. It is also shown that the use of compensation methods that do not take the sampling time into account leads to additional distortions. It is even possible that they exceed the distortions in an equivalent system without compensation.
机译:该报告提出了一种新的补偿方法,用于补偿与死区时间有关的失真,这些失真是由具有脉宽调制输出电压的B6逆变器引起的。尽管采样率较低,但新的补偿方法在直至磁场弱化区域的所有转速范围内均有效。无需额外的硬件即可实现。实验证明了该新方法的有效性。首先给出相关失真的描述,以便为开发提供基础。这考虑了场弱化区域,并提供了一种量化失真的说明性方法。还表明,使用未考虑采样时间的补偿方法会导致其他失真。甚至有可能在没有补偿的情况下超过等效系统中的失真。