Analysis of the mechanical properties of locking plates with and without screw hole inserts.

机译:分析带或不带螺纹孔嵌件的锁板的机械性能。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to determine if the use of screw hole inserts in empty locking screw holes improves the strength and failure characteristics of locking plates. Twenty 5-hole 1/3 tubular locking plates (Synthes, Paoli, Pennsylvania) were mounted on an oak dowel with a 1-cm gap simulating a fracture with comminution and bone loss. Ten of the 1/3 tubular plates had a screw hole insert placed in the center hole (centered over the simulated fracture), while 10 of the 1/3 tubular plates remained empty in the center hole. The plate-dowel constructs were placed in an Instron 8800 Material Testing Machine and subjected to a series of loading conditions, replicating physiologic loading. The torsional and axial stiffness of each plate-dowel construct was calculated. All plates were then loaded to failure. No significant differences were found in the mechanical properties of the 2 plate constructs. Both the filled screw-hole plate constructs and unfilled screw hole plate constructs demonstrated the same torsional and axial stiffness, before and after being subjected to a combined cyclic and axial torsional load. Additionally, there was no significant difference in ultimate compressive strength or load to failure. Locking plate technology is a relatively new innovation in orthopedic fracture fixation. The evolution of new and varied applications and implants continues. Persistent, fundamental questions exist concerning the basic locking plate design. This study demonstrates that the addition of screw hole inserts does not significantly change the stiffness, torsional strength, or axial loading strength of 1/3 tubular locking plates.
机译:这项研究的目的是确定在空的锁定螺孔中使用螺孔插入件是否可以提高锁定板的强度和破坏特性。将二十个5孔1/3管状锁定板(Synthes,Paoli,Pennsylvania)安装在橡木销钉上,缝隙为1厘米,模拟具有粉碎和骨丢失的骨折。 1/3的管状板中有10个在中心孔中(模拟裂缝的中心)有一个螺孔插入件,而1/3的管状板中有10个在中心孔中保持为空。将平板销钉构建体放入Instron 8800材料测试机中,并经受一系列加载条件,以复制生理学加载。计算了每个板销结构的扭转和轴向刚度。然后将所有板加载失败。在2个板构建体的机械性能中未发现显着差异。填充的螺孔板构造和未填充的螺孔板构造在承受循环和轴向扭转组合载荷之前和之后均显示出相同的扭转和轴向刚度。此外,极限抗压强度或破坏载荷没有显着差异。锁定板技术是骨科骨折固定术中的一个相对较新的创新。新的和多样化的应用和植入物的发展仍在继续。关于基本的锁板设计存在持久的基本问题。这项研究表明,增加螺孔嵌件不会显着改变1/3管状锁板的刚度,抗扭强度或轴向载荷强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号