Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of 3-Hole 4.5 mm Locking Compression Plate and 3-Hole 4.5 mm Narrow Dynamic Compression Plate, with Two Transarticular 5.5 mm Cortex Screws

机译:马近端指间关节的关节固定术:3孔4.5 mm锁定加压板和3孔4.5 mm窄动态加压板,带有两个经关节穿刺的5.5 mm皮质螺钉的生物力学比较

获取原文
获取原文并翻译 | 示例
           

摘要

ObjectivesTo compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws.Study DesignExperimental.Sample PopulationCadaveric adult equine forelimbs (*n=6 pairs).MethodsFor each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure.ResultsThere were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points.ConclusionBiomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.
机译:目的比较两种使用3孔4.5 mm锁定加压板(LCP)或3孔4.5 mm窄动态加压板(DCP)并同时使用2枚经关节穿刺术的马近端指间关节(PIP)关节固定术的生物力学特性5.5 mm皮质螺钉研究设计实验样本人群尸体成年马前肢(* n = 6对)方法对于每对前肢,将1个肢体随机分配给2个治疗组中的1个,默认将对侧肢体分配给另一个治疗组。在循环轴向载荷之前以及在四个,5000个循环载荷方案中的每一个之后,确定每种构造的构造刚度,在PIP接头上形成的间隙以及围绕PIP接头的旋转。经过20,000个周期的轴向加载方案后,每种构建体都被加载失败,结果在任何测量的时间点,LCP和DCP治疗组之间的构建体刚度,间隙形成或矢状面旋转均无显着差异。在所使用的测试条件下,具有3孔4.5毫米LCP的马PIP接头相当于用3孔4.5毫米窄的DCP固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号