Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values can lead to significant complications, including dislocation, leg-length discrepancy, impingement, accelerated bearing surface wear, and revisions. The purpose of this study was to assess whether robotic-assisted THA was reliable in predicting radiographic measurements of cup inclination and anteversion, leg-length change, and global offset change. All 61 robotic-assisted THAs that met the inclusion and exclusion criteria were performed by a single surgeon through a mini-posterior approach. Data provided by the robot were collected prospectively, and radiographic data were collected retrospectively by 2 blinded independent reviewers. The cohort in this study consisted of 27 male and 34 female patients, with an average age of 60.5 years. A strong inter-and intraobserver correlation was found for the radiographic measurements of cup inclination, cup anteversion, leg-length discrepancy, and global offset (r>0.8 with P<.001 for all). Ninety-six point seven percent of robotic-measured inclination angles and 98.4% of robotic-measured anteversion angles were within 10 degrees of radiographic measurements. One hundred percent of robotic-measured leg-length change and 91.8% of robotic-measured global offset change were within 10 mm of radiographic measurements. Robotic-assisted THA showed good predictive value for cup inclination and anteversion angles and measurements of leg-length change and global offset change done postoperatively on plain radiographs. Further refinement of the robotic system would make it more accurate in predicting the postoperative parameters mentioned.
机译:髋臼杯定位,腿长差异和整体偏移是与全髋关节置换术(THA)结局相关的重要参数。偏离可接受的值范围会导致严重的并发症,包括脱位,腿长差异,撞击,轴承表面磨损加快和翻新。这项研究的目的是评估机器人辅助THA在预测杯形倾斜和前倾,腿长变化和整体偏移变化的射线照相测量值方面是否可靠。由一名外科医生通过微型后路手术完成了所有符合纳入和排除标准的61个机器人辅助THA。由机器人提供的数据是前瞻性收集的,射线照相数据是由2位盲目的独立审阅者进行回顾性收集的。这项研究的队列包括27名男性和34名女性患者,平均年龄为60.5岁。在杯内倾角,杯前倾,腿长差异和整体偏移的放射线照相测量中发现,观察者之间和观察者内部具有很强的相关性(r> 0.8,P <.001)。百分之九十六的机械手测得的倾斜角和98.4%的机械手测得的前倾角均在X线照片测量范围内。机器人测量的腿长变化的百分之一百和机器人测量的全局偏移量的百分之91.8%在射线照相测量的10毫米内。机器人辅助的THA在平片上显示了对杯倾斜度和前倾角以及腿长变化和整体偏移变化的测量的良好预测价值。机器人系统的进一步完善将使其在预测所提及的术后参数方面更加准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号