Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening (n=23), septic loosenings (n=4), tibiofemoral instability (n=3), and wear (n=1). The Hospital for Special Surgery Knee Score and the Knee Society Roentgenographic Evaluation System were used. Statistical and cumulative survival rate analyses were performed. Average follow-up was 60.3 months (range, 32-100 months). The Hospital for Special Surgery Knee Score results indicated statistically significant improvement; the total score increased from 65.5 preoperatively to 88.4 postoperatively. Average range of motion increased from 90.9° preoperatively to 114.4° postoperatively. Radiographs showed no periprosthetic bone fractures or implant ruptures. Radiolucent lines were found in 20 of 26 patients and were progressive in 2 (both revised). Complications occurred in 10 patients. The rigidity of the hinge may be associated with a risk of aseptic loosening due to the increased stress transfer to the bone from the prosthesis through the locked hinge. Rotating-hinge knee implants provided acceptable mid-term outcomes for revision knee surgery with ligamentous instability. They are not at higher risk for early loosening unless short tibial stems are used. The high percentage of failures is more related to the complex surgery and to the status of the patients than to the hinged mechanism.
机译:旋转铰链膝关节植入物用于严重韧带不稳定和骨丢失的患者的全膝关节置换术。这项研究评估了一系列旋转铰链膝盖的结果。 31例NexGen旋转铰链膝盖(Zimmer,华沙,印第安纳州)被植入29例患者中(2个双侧),平均年龄为72.8岁。手术适应症包括无菌性松动(n = 23),脓毒性松动(n = 4),胫骨股骨不稳定性(n = 3)和磨损(n = 1)。使用了特殊外科医院膝关节评分和膝关节X线照相评估系统。进行统计和累积生存率分析。平均随访时间为60.3个月(范围32-100个月)。特殊外科医院膝关节评分结果表明统计学上有显着改善;总分从术前的65.5提高到术后的88.4。平均运动范围从术前的90.9°增加到术后的114.4°。放射线照片未显示假体周围的骨折或植入物破裂。在26例患者中有20例发现了射线可透线,在2例中均进行了放疗(均已修订)。 10例患者发生并发症。铰链的刚度可能与无菌松动的风险有关,这是由于从假体通过锁紧的铰链传递到骨骼的应力增加所致。旋转铰接膝关节植入物为韧带不稳定的翻修膝关节手术提供了可接受的中期结果。除非使用短胫骨茎,否则它们没有较高的早期松动风险。较高的失败率与复杂的手术和患者的状况有关,而不是与铰接机构有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号